Please Wait a Moment
X

Infor LX Tips, Infor LN Tips, BPCS Tips, Baan Tips, Infor M3 Tips & Infor ERP News

Crossroads Connections

Infor ERP Tips & News from the Experts

Infor LX | Infor LN | BPCS | Baan | Infor M3

BPCS/LX Tip of the Week: Need a Productivity Boost?

Anthony Etzel 0 38274 Article rating: No rating

Are your employees not as productive as you’d like them to be? Are jobs not getting completed on schedule? Without actual data, making decisions about how efficient your operation is will be difficult. Start tracking actual time to complete each operation. Compare different production lines running the same job. Is one line running more efficiently? If so, start looking at why. Track downtime, setup, etc. Once you start really analyzing each piece of the puzzle, you can begin to uncover areas that are ripe for improvement.

Optimize Your Manufacturing Today!

Baan/LN Tip of the Week: How Are You Generating Financial Statements?

Kathy Barthelt 0 66786 Article rating: No rating

If you’re not already, consider generating your financial statements directly out of Baan/LN. In the Financial Statements module, you can define and print financial and consolidated statements. These statements can be based on various cross sections of your General Ledger account and dimension structure. You can also define cash flow statements, which can be based on cash flow reasons.

Optimize Your Manufacturing Today!

BPCS/LX Tip of the Week: Create a Culture of Engaged Problem Solvers

Anthony Etzel 0 35578 Article rating: No rating

When there is a problem, making a decision in a vacuum is the worst thing you can do.

Get input from others within your organization. If possible, consult those at various levels. By being open with others as to the nature of the problem, and enlisting their help in determining the right solution, resistance to the recommended solution is quite often greatly reduced.

Optimize Your Manufacturing Today!

Baan/LN Tip of the Week: Create a Culture of Engaged Problem Solvers

Kathy Barthelt 0 62131 Article rating: No rating

When there is a problem, making a decision in a vacuum is the worst thing you can do.

Get input from others within your organization. If possible, consult those at various levels. By being open with others as to the nature of the problem, and enlisting their help in determining the right solution, resistance to the recommended solution is quite often greatly reduced.

Optimize Your Manufacturing Today!

CROSSROADS MES VERSION 11.2 RELEASED

Anthony Etzel 0 30825 Article rating: 5.0

Crossroads RMC is proud to announce the official release of Crossroads MES Version 11.2

Included in this release are many new features including: Priority Code Display, Capacity Load Balancing, Indirect Time Reporting, T.L Ashford Label Integration, In-Line Label Validation, and a new XML Dashboard Interface. 
Improvements have been made to the ERP Interface, Manual Labor Time Capture, Parts List Display, Setup Operation, and End of Shift Review.

Crossroads MES for BPCS/LX has been around since 1995. Your input is important to us. Many of our improvements and functions come from your requests, so please share your ideas.

Future Functionality Coming Soon!

  • Employee/Shop Order Efficiency
  • IDF Reporting
  • Field Size Expansion
  • Non-windows tablet version

Click here for more details

BPCS/LX Tip of the Week: 4 Reasons You Need Timely & Accurate Data

Anthony Etzel 0 45211 Article rating: No rating

Seems obvious – you want real time data and you want it to be accurate. Do you have the systems in place to allow for this?

Here are 4 reasons you need a data collection system:

  1. See the differences between actuals and standards
  2. Determine the source of project overruns
  3. Prevent mis-shipments to customers
  4. Avoid unnecessary reordering of parts

An automated data collection system will analyze your current data, allowing you to efficiently optimize your manufacturing and the benefits will be huge and far reaching.

Optimize Your Manufacturing Today!

Baan/LN Tip of the Week: 4 Reasons You Need Timely & Accurate Data

Kathy Barthelt 0 63525 Article rating: No rating

Seems obvious – you want real time data and you want it to be accurate. Do you have the systems in place to allow for this?

Here are 4 reasons you need a data collection system:

  1. See the differences between actuals and standards
  2. Determine the source of project overruns
  3. Prevent mis-shipments to customers
  4. Avoid unnecessary reordering of parts

An automated data collection system will analyze your current data, allowing you to efficiently optimize your manufacturing and the benefits will be huge and far reaching.

Optimize Your Manufacturing Today!

BPCS/LX Tip of the Week: How is your relationship going... with your suppliers?

Anthony Etzel 0 43762 Article rating: No rating

Do you have a strong relationship with your suppliers? Do they know your every need/want? No? Well, why not?  

The key to any good relationship is communication. Have you established clear and consistent communication with your suppliers? Consider establishing a way for both of you to share information with each other electronically.

A portal is a good way to achieve this. Documents can be shared, updates on deliveries can be communicated with ease, and changes that can affect both your operations and theirs can be communicated efficiently and effectively.

Optimize Your Manufacturing Today!

First91929394969899100Last

Tips:  LX | BPCS | M3

Item Facility Master has a new attribute to define the override inspection days lead time CICP.ICINSD.

  • When an item facility has a defined override inspection days lead time, that value will be used instead of the system parameter inspection days lead time.

MRP exception report, MRP200B
Purchase planning report, PUR285B
Purchase order / Requisition maintenance, PUR500D3
Purchase order consolidation / release, PUR640B1
Vendor splits, PUR653B

This enhancement improved the subfile utilized in MRP320D Master Schedule Detail Inquiry -SCR001 by expanding the subfile with data rather than clearing the subfile as user pages. This change provides full support for the WebTop 4.8 Grid decorator.

This enhancement updated the approach used to populate the subfile to allow a deployed Webtop Grid to function correctly. There is no visible or user-impacted change to the way the program functions.

This enhancement provides improved functionality and full support of a Webtop grid applied to the subfile.

Last

Tips: LN | Baan

Kathy Barthelt
/ Categories: Infor LN & Baan Tips

Infor LN & Baan Tip: Performance improvement by setting the First Free Number Cache (tcmcs0651m000)

Many transactions in all kinds of modules use order numbers or serial numbers. These order numbers are most often automatically generated. In the Number Groups (tcmcs0151m000) session you can define groups of order numbers used for dedicated areas. A Number Group is a group of the first free number series that you can assign to a specific use. All the numbers that Infor LN generates in the number groups that are dedicated to the same purpose are unique.

All the first free numbers are stored in the table tcmcs050.

As many different processes can request a free number from the number groups, we often see delays in the performance, due to locking on the first free number records. This locking issue can have a severe impact on the performance of huge batch-type transactions, but also on the performance perceived by individual users in many areas in LN.

For example:

  • Processing warehouse transactions. Single or in-batch
  • Completing / closing orders
  • Backflushing of production orders
  • Generate Order Planning
  • Cost calculation and warehouse revaluation


How this performance can be improved?

Resolution

In the Number Groups (tcmcs0151m000) session you can open the details of a specific Number Group (tcmcs0651m000) or start the session stand-alone.

In the Number Group, you define the Series with the related First Free Numbers. Per Serie in the First Free Number, you have the option to define the Cache Size.

This Cache size is defaulted on a value of 0 (zero). A cache size of zero means No Cache. How does the First Free Number caching works:

  • When the Cache Size is zero: With this setting a process requests a Free Number from the Serie and the first free number is issued to the process. But the first free number record is not updated yet. At the moment the requesting process is finished, without errors, it reports back that the number is used and the first free number record is updated. All the time that the process is working on the transactions the first free number record is locked. If another process is requesting a free number from the same series, it must wait (retries) until the record is updated and released by the previous process. This is the locking which is causing delays in the other processes.  
  • Setting the Cache Size to a higher value then zero activates the caching. When the Cache Size is set to 1 or higher, the requested free number is sent to the requesting process, the first free number is updated, with the number as defined in the Cache size, and the record is saved. It does not wait until the requesting process has reported back that is finished, with or without errors. In this way the record is immediately released and no locking will occur. If another process is requesting a free number, it does not need to wait until the free number record is released by the earlier process. If the process is ended with errors and therefor the number is not used, this number from the series is lost. This can result in gaps in the numbering. When the cache size is greater than 1, for example it is set to 5, the requesting process receives 5 free numbers. Even if it only needs less than 5. In this way the process only has to request for a new free number after it has used the first 5 numbers from the cache. This will also speedup the process in case of large batch transactions. For ‘warehouse integration users’, like for example Factory Track or WMS users we advise to set the cache size to 5.  

Note that financial documents are not based on number group series / first free numbers. Instead they are based on transaction type series, for which the caching functionality does not exist. Financial documents, like sales invoices, bank transactions, are thus not cached.

The caching is especially important to improve the performance of all logistical processes.

It is strongly recommended (mandatory) to set the Cache Size for all Number Groups to a minimum of 1.

Previous Article Infor LX / BPCS & Infor LN / Baan Tip: A New Wave of Cyber Attacks: Five Actions to Take Now
Next Article ​Infor LN & Baan Tip: Determining What Data to Archive or Delete
Print
23565 Rate this article:
5.0
Kathy Barthelt

Kathy BartheltKathy Barthelt

Other posts by Kathy Barthelt

Contact author

x

Categories