Infor LN & Baan Tips & Tricks for FINANCE: Interest Invoices

Kathy Barthelt 0 13269 Article rating: 5.0

You can generate interest invoices for paid invoices, partially paid invoices, and unpaid invoices. In addition, after you generate and send an interest invoice, you can generate a subsequent interest invoice for the next period.

Setting up interest invoicing: You can set up interest invoicing in Accounts Receivable and the General Ledger.
To set up interest invoicing, use these sessions:

  • Invoice-to Business Partner (tccom4112s000)

For invoice-to business partners...

Infor LX/BPCS Tips & Tricks for FINANCE: Creating Configurable Macros (CEA)

George Moroses 0 14633 Article rating: 5.0

You can create new macros in the Infor LX Configurable Enterprise Financials CEA107. 

On the Macro Definition window, you define the source file and the field in which you perform an arithmetic or special operation. For example, you can create a macro to accrue sales commission based on revenue. Your source file and field are the Invoice Line History (SIL) file and the G/L revenue (ILREV) field. 

Select Functions to access the Macro Functions window, on which you define the arithmetic, character, or special operation to process against the defined source field. In the previous example of accrued sales commission, you enter an arithmetic operation of multiply (*) and an operand value for the percentage, such as 0.05 for five percent. 

Note:  Previously created user defined macros will have to be updated to include any expanded field sizes in V84. 

Infor LX/BPCS Tips & Tricks for TECHNOLOGY: Setting Up User Groups (CEA)

George Moroses 0 11762 Article rating: 5.0

To utilize the Security Rules Optimization feature, a system administrator can assign security codes to 100 pre-defined user groups. User groups are created in the Group Security Maintenance (SYS603) program. All users assigned to this group possess the same level of security.   

A system administrator can assign security codes for up to 100 of the user groups. All user groups over 100 are still administered by all security reject/allow rules assigned to them but are not able to utilize the optimized process. 

Each of the security codes and access levels are assigned to user groups and are mapped to the account strings and stored in the Account Cross Reference (CEA106D1) file.   

Once security codes have been assigned, the system administrator must: 

  • Determine which level each group is allowed access.

  • Determine which segment values/account strings are assigned to which user groups.

  • Create security rules for specific segment values/account strings and assign these groups to the created rules.

  • Select the rules to be processed.  Processing can be done in either batch mode or interactively.

  • The Security Rules flag must be on in the CEA Control Parameters program before any rules are effective. 

Infor LX/BPCS Tips & Tricks for OPERATIONS: Lot Expiration Date

George Moroses 0 11028 Article rating: 5.0

This feature provides a parameter that allows the user to enter expiration dates on the Inventory Transaction Posting screen, INV500, and Purchase Order Receipts screen, PUR5505, when they have received a lot controlled item that is not QMS controlled. This new field allows an expiration date to be entered and not overridden. A system parameter was added to Advanced Process Industries Parameters, API820D. When the parameter is set to Yes, a new lot expiration date is available in the Inventory Transaction Posting, INV500D2, and Purchase Order Receipts, PUR550D2, screens.

Infor News You Can Use: LN NAUG Face-to-Face Annual Meeting 2025

May 13-15, 2024 | Chicago Marriott - Naperville IL

Kathy Barthelt 0 7773 Article rating: 5.0

We are delighted to invite you to the 2025 Annual LN NAUG Face-to-Face Event —a special premier event for Infor LN and Baan users of North America. This is your chance to connect with fellow users, share experiences, and shape the future.

  • Learn from the Best: Engage with industry leaders and experts through keynote sessions and panel discussions.
  • Increase your Skills: Participate in collaborative breakout sessions to explore available solutions.
  • Network & Connect: Build relationships with other customers, potential collaborators, and industry pioneers.


Register today to claim Early Bird pricing through March 31, 2025.
https://www.lnnaug.org/events/2025-f2f-annual-meeting 

 

123578910Last

Tips:  LX | BPCS | M3

Item Facility Master has a new attribute to define the override inspection days lead time CICP.ICINSD.

  • When an item facility has a defined override inspection days lead time, that value will be used instead of the system parameter inspection days lead time.

MRP exception report, MRP200B
Purchase planning report, PUR285B
Purchase order / Requisition maintenance, PUR500D3
Purchase order consolidation / release, PUR640B1
Vendor splits, PUR653B

This enhancement improved the subfile utilized in MRP320D Master Schedule Detail Inquiry -SCR001 by expanding the subfile with data rather than clearing the subfile as user pages. This change provides full support for the WebTop 4.8 Grid decorator.

This enhancement updated the approach used to populate the subfile to allow a deployed Webtop Grid to function correctly. There is no visible or user-impacted change to the way the program functions.

This enhancement provides improved functionality and full support of a Webtop grid applied to the subfile.

Last

Tips: LN | Baan

George Moroses

Infor LX & BPCS Tip: PowerLink

PowerLink is a Windows-based client for end-users within the Infor Development Framework (IDF). PowerLink allows exports/imports from/to the ERP database, but how much do you really know about it? Here is some helpful information about PowerLink.​

Why does PowerLink sometimes fail to export all records?
There's not a finite amount of records that PowerLink can export. However, PowerLink export was never intended to handle large volumes of data. It was designed as a quick snapshot of a fairly small subset and a simple view of the user's PowerLink card. 

What is the maximum amount of data that can be exported?
The maximum number of records is only limited by the system resource like memory, etc. When the system runs out of resources, an OutOfMemory error should occur. In previous testings, we have exported +1 million records, although the size of records differs greatly between business objects, the total size of the data could be an issue. For larger volumes of data, customers should investigate other tools such as the iSeries Access "Data Transfer from iSeries Server" feature to download directly to Excel.

How do I know if the size of the data is an issue?
1. When exporting to an external file (text, HTML) then importing to Excel: You can easily check the output (text, HTML) to see if the intermediate output has all the records. This can be done by visual inspection or through the use of column totals. Simply compare between the output and what you see in PowerLink. If the exported file has all the records, then the problem is definitely Excel.
2. When exporting to clipboard, then copy/paste to Excel: There is a clipboard export size limit that is controlled through client preferences. Check the exported data in the clipboard, and see if it contains all the records or only partial records due to the size limitation set in client preferences. If limited, change the client preferences using Customize from the Main browser > Preferences > Miscellaneous tab > Limit Clipboard Export, and try the export again. If the clipboard has all the records the problem is in Excel, which we don't have jurisdiction over.

Suggestions for improving the export process. 

  1. Reduce the number of columns seen in the view. This will serve to reduce the data being exported and may increase the number of records that can be exported. 
     
  2. Reduce the complexity of the view. If the view has one column that lives on a related object, then it has to build SQL behind the scenes to get that related record. If all of the columns come from a single business object, then the processing will be significantly faster.
     
  3. Export to HTML, which can be opened directly by Excel, Access, and many other programs. This reduces the processing of the export formatting because PowerLink needs only to put begin and end tags around each data element. This will also preserve column alignment when Excel or other programs open the file.
     
  4. Unless you are exporting a fairly small volume of data, export to a file, not clipboard. Clipboard is held in memory until the entire view is read, and records are written to the file as they are retrieved.
     

 Also see KB 1357068 for more information about testing your view.