Please Wait a Moment
X

Infor LX Tips, Infor LN Tips, BPCS Tips, Baan Tips, Infor M3 Tips & Infor ERP News

Crossroads Connections

Infor ERP Tips & News from the Experts

Infor LX | Infor LN | BPCS | Baan | Infor M3

Flexfab Expands Their Use of Crossroads RMC Data Collection for All LN Installations Globally

Data Collection News

Kathy Barthelt 0 28606 Article rating: 5.0

Flexfab Horizons International, Inc, a global leader in the manufacture of high performance silicone and other advanced polimer products, has made the decision to expand their use of Crossroads RMC’s Data Collection Solution, RMC3, to their China location. The initial implementations in Nottinghamshire, UK and the United States took place in 2018, and the China implementation is expected to be completed by Q2 of 2019. All installations focus on improvements in warehouse management in Infor LN. Applications implemented include Receiving, Inspections/Approvals, Putaway, Stock Transfers and Stock Inquiry.

Crossroads RMC partnered with Electrolux Corporation to Connect Baan IVc4 to Vertex 8.0 (O Series)

Vertex Q to Vertex O… the ABC’s of tying this to Baan IV

Kathy Barthelt 0 24619 Article rating: No rating

Crossroads RMC partnered with Electrolux Corporation to Connect Baan IVc4 to Vertex 8.0 (O Series), and was able to successfully complete this project in under 3 months. This project was completed using Crossroads RMCconnector as a web service to read the Vertex tax data and pass the information back into Baan for further processing. Triggers were created to handle the following processes:

  • Sales Order Lines
  • Print/Reprint Order Acknowledgement
  • Print Sales Invoice (Both compose and final)
  • Purchase Order Lines
  • Purchase order Acknowledgement
  • Purchase Order invoice
  • Manual Finance Invoice (Compose, print and post)
  • Post Integration transactions
  • Finalize batch

Nazdaq has released Version 3.0 of B2Win Suite

Partner News

Kathy Barthelt 0 38849 Article rating: No rating

New Release of B2Win Suite: Format customer reports, email documents to your suppliers and customers, and more! 

New features – B2Win Suite - You are no longer limited to the data that comes from your canned reports! You can now add new columns to your already existing reports in Excel, based on SQL commands that bring additional data from any database (ERP or other), based on values from the report.

Existing Nazdaq customers should contact us to learn how we can convert your software to the latest and greatest Nazdaq product suite!

For more information: watch our webinar:

Webinar Recording: 48:18

Crossroads is proud to work with Johnson Crushers International on their LN re-implementation to 10.6

Kathy Barthelt 0 19958 Article rating: 5.0

Johnson Crushers International (JCI), a global leader in engineering and manufacturing full lines of cone crushers, horizontal and incline vibrating screens and track-mounted, portable and stationary crushing and screening plants, has selected Crossroads RMC to help them re-implement Infor LN on 10.6.  JCI’s main objectives with this project are to support their continued growth, align and standardize their business processes, and enable a continuous improvement effort to drive additional value to the business. Go live is expected to occur in early Q1 of 2020.

Baan/LN Tip of the Week: Warehouse Material Movement / Problems With the Inventory Structure Table (whinr150)

Kathy Barthelt 0 82168 Article rating: 5.0

This has come up as an issue during various stages of warehouse material movements – transfers, outbounds, shipments. We have seen it right up to 10.4. The inventory structure table (whinr150) becomes a problem. The error points to that table, but users are lost as to how to fix it.

In the session Units by Unit Set many companies let the field Storage default to Yes. If the UOM is not intended to be used in inventory then that setting should be No. 

If an item is purchased in UOM different from the inventory unit and the setting is Yes then LN adds a record in that UOM to the inventory structure table. It is that record that causes problem later.

The session has an option to change the value of the storage field. Specific > Convert Use for Storage. This option works both ways and will correct all inventory in the UOM range. 

Should a user receive an error that references inventory structure table then the solution is to check that session to see if an odd UOM exists in it. If so use the Convert Use for Storage to correct the problem.

Baan/LN Tip: Disabling Unused Functionality in LN

Kathy Barthelt 0 80163 Article rating: No rating

If functionality such as Commissions, Rebates, or Contracts are enabled in the parameters, LN checks this functionality during transactions, even if you did not specify anything for these concepts. Therefore, if you do not use certain functionality within LN, to improve performance, disable the corresponding parameter.

Optimize Your Manufacturing Today!

Crossroads RMC named as Avalara's Certified Integration Partner for Infor LX

Anthony Etzel 0 29638 Article rating: 5.0

Avalara Announces 41 Newly-Certified Integrations Into Business Application


December 20, 2018 05:00 AM Eastern Standard Time

SEATTLE--()--Avalara, Inc. (NYSE:AVLR), a leading provider of cloud-based tax compliance automation for businesses of all sizes, today announced the release of 41 newly-certified integrations with accounting, ERP, ecommerce, point-of-sale, mobile commerce, and CRM software applications.

Avalara has been a partner-centric company since its founding in 2004, with a keen focus on integrating with technology solutions already in use by existing and future customers. Avalara Certified integration partners have met criteria developed by Avalara to guarantee each integration’s performance and reliability. Certified integrations are built to ensure customers enjoy a fast, reliable, and easy process for embedding Avalara’s automated tax management into existing systems.

Additionally, these integrations enable customers of Avalara partner solutions to benefit from Avalara’s real-time calculation of applicable taxes, fees, and surcharges for billing line items. Avalara software reduces the tedium and complexity of determining taxes for millions of products and services across the U.S., Canada, Europe, and other international jurisdictions, giving customers more time to focus on driving their own business success.

The latest group of Avalara Certified integrations includes:

  • Infor LX (by Crossroads RMC) is an ERP solution used primarily by manufacturers.

Baan & LN Tip of the Week: Get Real!

Kathy Barthelt 0 81851 Article rating: No rating

You’ve got an ERP system, so everything should be real-time and everyone should have access to information in real-time, right? RIGHT?!

Why not? Why are there spreadsheets, and separate Access databases off to the side?

Data loses value over time, so why not give everyone up to date, accurate information all the time? Take a look at those silos of information and see how you can eliminate them. Your business will benefit greatly as a result.

Optimize Your Manufacturing Today!

First8081828385878889Last

Tips:  LX | BPCS | M3

Tips: LN | Baan

George Moroses

Infor LX & BPCS Tip: PowerLink

PowerLink is a Windows-based client for end-users within the Infor Development Framework (IDF). PowerLink allows exports/imports from/to the ERP database, but how much do you really know about it? Here is some helpful information about PowerLink.​

Why does PowerLink sometimes fail to export all records?
There's not a finite amount of records that PowerLink can export. However, PowerLink export was never intended to handle large volumes of data. It was designed as a quick snapshot of a fairly small subset and a simple view of the user's PowerLink card. 

What is the maximum amount of data that can be exported?
The maximum number of records is only limited by the system resource like memory, etc. When the system runs out of resources, an OutOfMemory error should occur. In previous testings, we have exported +1 million records, although the size of records differs greatly between business objects, the total size of the data could be an issue. For larger volumes of data, customers should investigate other tools such as the iSeries Access "Data Transfer from iSeries Server" feature to download directly to Excel.

How do I know if the size of the data is an issue?
1. When exporting to an external file (text, HTML) then importing to Excel: You can easily check the output (text, HTML) to see if the intermediate output has all the records. This can be done by visual inspection or through the use of column totals. Simply compare between the output and what you see in PowerLink. If the exported file has all the records, then the problem is definitely Excel.
2. When exporting to clipboard, then copy/paste to Excel: There is a clipboard export size limit that is controlled through client preferences. Check the exported data in the clipboard, and see if it contains all the records or only partial records due to the size limitation set in client preferences. If limited, change the client preferences using Customize from the Main browser > Preferences > Miscellaneous tab > Limit Clipboard Export, and try the export again. If the clipboard has all the records the problem is in Excel, which we don't have jurisdiction over.

Suggestions for improving the export process. 

  1. Reduce the number of columns seen in the view. This will serve to reduce the data being exported and may increase the number of records that can be exported. 
     
  2. Reduce the complexity of the view. If the view has one column that lives on a related object, then it has to build SQL behind the scenes to get that related record. If all of the columns come from a single business object, then the processing will be significantly faster.
     
  3. Export to HTML, which can be opened directly by Excel, Access, and many other programs. This reduces the processing of the export formatting because PowerLink needs only to put begin and end tags around each data element. This will also preserve column alignment when Excel or other programs open the file.
     
  4. Unless you are exporting a fairly small volume of data, export to a file, not clipboard. Clipboard is held in memory until the entire view is read, and records are written to the file as they are retrieved.
     

 Also see KB 1357068 for more information about testing your view.

Print
55836 Rate this article:
5.0
George Moroses

George MorosesGeorge Moroses

Other posts by George Moroses

Contact author

x

Categories