Reskilling and Upskilling Your Staff – Why You Shouldn’t Ignore This

Crossroads RMC 0 12828 Article rating: 5.0

According to the World Economic Forum, half of all employees will require significant reskilling or upskilling by 2025.

For many of you, your Infor ERP system was implemented 5, 10, 15, or 20+ years ago, and now there are only a handful of people left from that implementation if any at all. Since most of your "how and why" walked out the door, how much longer can you get by on “tribal knowledge”? While many companies understand the importance of employee training, implementing that training remains a challenge. What’s the best way to proceed you ask?

Infor LN & Baan Tip: What conditions must exist before changing an item's inventory unit?

Kathy Barthelt 0 53376 Article rating: 5.0

Is there a procedure for changing an item’s inventory unit? What conditions must exist before it can be done?

Once inventory transactions (receipts or issues) have occurred for an item, the inventory unit cannot be changed. If only orders have been placed against the item (sales or purchase), the inventory unit can be changed if these...

Infor LX & BPCS Tip: 4 Approaches to Customizing LX / BPCS - Preparing for a Future Upgrade

George Moroses 0 21393 Article rating: 5.0

How do I modify BPCS/LX to allow for the ease of upgrading in the future?

  1. Exit Points...

Is it time to get more out of your ERP?

Crossroads RMC 0 12391 Article rating: 5.0

As crazy as it sounds, we’re about to enter the 2nd half of 2023. How are you doing on your 2023 goals? Planning for 2024 projects?
Maybe it's time to get more out of your Infor ERP system.

OFF SUPPORT AND MAINTENANCE WITH INFOR AND FEEL STUCK?

⇒⇒ TIME TO UPGRADE?

⇒⇒ NOT UPGRADING?

Infor LX & BPCS Tip: Support for IBM i 7.3 and Infor LX Products

George Moroses 0 19345 Article rating: 5.0

On September 30, 2022, IBM® announced the end of support of IBM i operating system 7.3 effective September 30, 2023. In line with IBM’s support policy, Infor will no longer support LX and related products on IBM i 7.3 after May 31, 2024. All Infor LX releases, patches, and related solutions are...

Have You Heard About the Latest & Greatest Way to BOOST Productivity?

LIFE HACKS

Kathy Barthelt 0 22477 Article rating: 5.0

In a world of life hacks and constantly changing routines, we could all use help boosting productivity.

With Crossroads RMC support services, boosting your productivity just got 10x easier! Boost the productivity of your entire team by adding just ONE team member that you only pay when you need them. And the best part is that they are waiting for your call right now and every hour of every day, even on weekends and holidays.

Check out Crossroads RMC's Support Services Designed YOUR Way: ...

First1920212224262728Last

Tips:  LX | BPCS | M3

Item Facility Master has a new attribute to define the override inspection days lead time CICP.ICINSD.

  • When an item facility has a defined override inspection days lead time, that value will be used instead of the system parameter inspection days lead time.

MRP exception report, MRP200B
Purchase planning report, PUR285B
Purchase order / Requisition maintenance, PUR500D3
Purchase order consolidation / release, PUR640B1
Vendor splits, PUR653B

This enhancement improved the subfile utilized in MRP320D Master Schedule Detail Inquiry -SCR001 by expanding the subfile with data rather than clearing the subfile as user pages. This change provides full support for the WebTop 4.8 Grid decorator.

This enhancement updated the approach used to populate the subfile to allow a deployed Webtop Grid to function correctly. There is no visible or user-impacted change to the way the program functions.

This enhancement provides improved functionality and full support of a Webtop grid applied to the subfile.

Last

Tips: LN | Baan

George Moroses

Infor LX & BPCS Tip: PowerLink

PowerLink is a Windows-based client for end-users within the Infor Development Framework (IDF). PowerLink allows exports/imports from/to the ERP database, but how much do you really know about it? Here is some helpful information about PowerLink.​

Why does PowerLink sometimes fail to export all records?
There's not a finite amount of records that PowerLink can export. However, PowerLink export was never intended to handle large volumes of data. It was designed as a quick snapshot of a fairly small subset and a simple view of the user's PowerLink card. 

What is the maximum amount of data that can be exported?
The maximum number of records is only limited by the system resource like memory, etc. When the system runs out of resources, an OutOfMemory error should occur. In previous testings, we have exported +1 million records, although the size of records differs greatly between business objects, the total size of the data could be an issue. For larger volumes of data, customers should investigate other tools such as the iSeries Access "Data Transfer from iSeries Server" feature to download directly to Excel.

How do I know if the size of the data is an issue?
1. When exporting to an external file (text, HTML) then importing to Excel: You can easily check the output (text, HTML) to see if the intermediate output has all the records. This can be done by visual inspection or through the use of column totals. Simply compare between the output and what you see in PowerLink. If the exported file has all the records, then the problem is definitely Excel.
2. When exporting to clipboard, then copy/paste to Excel: There is a clipboard export size limit that is controlled through client preferences. Check the exported data in the clipboard, and see if it contains all the records or only partial records due to the size limitation set in client preferences. If limited, change the client preferences using Customize from the Main browser > Preferences > Miscellaneous tab > Limit Clipboard Export, and try the export again. If the clipboard has all the records the problem is in Excel, which we don't have jurisdiction over.

Suggestions for improving the export process. 

  1. Reduce the number of columns seen in the view. This will serve to reduce the data being exported and may increase the number of records that can be exported. 
     
  2. Reduce the complexity of the view. If the view has one column that lives on a related object, then it has to build SQL behind the scenes to get that related record. If all of the columns come from a single business object, then the processing will be significantly faster.
     
  3. Export to HTML, which can be opened directly by Excel, Access, and many other programs. This reduces the processing of the export formatting because PowerLink needs only to put begin and end tags around each data element. This will also preserve column alignment when Excel or other programs open the file.
     
  4. Unless you are exporting a fairly small volume of data, export to a file, not clipboard. Clipboard is held in memory until the entire view is read, and records are written to the file as they are retrieved.
     

 Also see KB 1357068 for more information about testing your view.

Print
49443 Rate this article:
5.0
George Moroses

George MorosesGeorge Moroses

Other posts by George Moroses

Contact author

x