Steps to undo an IDF modification and restore to the default

Changes are great, but if you want to undo an IDF modification and restore to the default, you need to follow these steps:

Reset to an Infor shipped view (“un-modify” it)

  1. Open the public node of an object you would like to reset to the shipped status. Notice that all of the standard views (i.e., those owned by Infor) are unmodified.
  2. Select the row with the Modified column = yes
  3. Select the Reset to default button on the toolbar
  4. Say Yes to the prompt
  5. The object is now back to the way it was shipped by Infor. Note that it now shows that it has not been modified. If you display the editor, you will see that the attribute you deleted has been restored. Note that only objects owned by Infor can be reset. If you change a standard definition, and later regret it, you can use this feature to restore it with a couple of clicks.
Previous Article How to Improve Customer Shipments With OTTO - A Case Study
Next Article Tax Law Changes by the Numbers - Infor LX & BPCS Integration to Avalara
Print
38134 Rate this article:
5.0
Anthony Etzel

Anthony EtzelAnthony Etzel

Other posts by Anthony Etzel

Contact author

Please solve captcha
x

Tips:  LX | BPCS | M3

These programs are used to capture and post shop floor information. Labor reporting, machine time, etc. can be captured by either program. The key difference is that one will also capture the production receipt and backflush components. Based on your company information / transaction process, one of these programs will most likely be used daily to capture current shop floor data. You can use the shop packet labor ticket for the manual recording, and the keying of the data. Alternatively, you can incorporate an automated method like an MES solution to capture the data and streamline the process.

The bubble number is maintained at the component level for each component defined on the Bill of Material. It is an extra user-defined reference number that you can use to re-sequence the maintenance screen display or bills of material listings.

In Infor LX, the system displays the bubble number for the existing child items. Engineering drawings often use a bubble number at the component level on the drawing so that same bubble number can be used on the Bill of Material for a link of the component to the drawing. Alternatively, you may use it simply as a method to sequence the BOM.