Infor LN & Baan Tip of the Week: New Inventory Aging Analysis Report – 10.7

A new standard Inventory Aging report can be printed in the Perform Inventory Aging Analysis (whina1440m000) session. This report is mainly based on the physical incoming and outgoing inventory movements and transactions. The date of inventory consumption or issue is compared to the date of receipt. If inventory is not yet issued, a reference date is used for aging calculation.

The report includes this information:

  • Which inventory items are not frequently used or are obsolete.
  • How long items have been stored in a warehouse.
  • Inventory and transaction values. This facilitates the financial auditing process.

To use this new feature, an inventory aging analysis definition must be available in the Inventory Aging Analysis Definition (whina1140m000) session.

Previous Article Infor LX & BPCS Tip of the Week: Order Entry Line Copy Feature – LX 8.4
Next Article Infor LX & BPCS Tip of the Week: Expanded Amount Fields on the Period End Calculation Reports – LX 8.4
Print
59925 Rate this article:
5.0
Kathy Barthelt

Kathy BartheltKathy Barthelt

Other posts by Kathy Barthelt

Contact author

Please solve captcha
x

Tips:  LX | BPCS | M3

BPCS/LX Tip of the Week: SFC600

In addition to SFC650, this ERPLX program is also used to capture and post shop floor information.

The key difference between the two is that SFC600 only captures Labor (run time) reporting, machine time, downtime and indirect time.

If you use SFC600, then all shop order material receipts and issues would be captured using INV500.

Both Inventory and Shop Floor Transaction entry is keyboard dependent, unless you incorporate an automated method like an MES solution to capture the data.

Using SFC600 to enter downtime.

You are tracking downtime and using SFC600 to enter the downtime, but you don’t know where to go to setup downtime reasons. You can set up the downtime reason codes in the INV application by selecting the reason code maintenance program INV140D1.

Once you are in the reason code maintenance program, position to the transaction effect code “D”. Using the transaction effect code “D” you can now setup as many downtime reason codes as needed. The reason code field is alpha numeric, so be creative with your reason code assignments.