Please Wait a Moment
X

Infor LX Tips, Infor LN Tips, BPCS Tips, Baan Tips, Infor M3 Tips & Infor ERP News, Crossroads Connection

How often are you counting your inventory? Are inaccurate counts affecting your ability to satisfy customer orders?

Infor LX | BPCS | Infor LN | Baan

Crossroads RMC 0 26821 Article rating: 5.0

Crossroads RMC Cycle Counting Applications provide:

  • Increased inventory accuracy.
  • The ability to review & approve count before direct update of LN/Baan tables.
  • The elimination of unnecessary re-orders of items with current inventory.
  • Greater ability to satisfy customer orders due to accurate inventory levels.
  • Direct labor cost savings – less staff required for count.
  • Increased productivity during count – counts reduced from weeks to a day.


Learn more about Cycle Counting for Infor LX & BPCS> 

Learn more about Cycle Counting for Infor LN & Baan> 

Infor LX & BPCS Materials Tip: Unique ID Generator / Unique Sequence Number

George Moroses 0 24719 Article rating: 5.0

Serial Number Unique ID Generator - The new Serial Number Unique ID Generator program (INV599B3) is used to generate a unique value that groups a set of serial numbers that should be treated as part of a single, comprehensive set of inventory transactions.

Assign Unique Sequence Number - The new Assign Unique Sequence Number program (SYS046B) is used by any program that posts an inventory transaction, that is, writes an...

Infor LN & Baan Tip: Can You Backflush An Item If Estimated Quantity is Zero?

Kathy Barthelt 0 51106 Article rating: 5.0

Yes, you can backflush an item with an estimated quantity = 0.00 if you haven't already backflushed the order. For example, you had an order with one component, you reported the quantity at the operation or order level and ran the backflush. Now you realize you need another component added. In this example, the order has already been backflushed, so if you were to add a second component, run backflushing, nothing would happen.

Backflushing is based on the 'quantity to backflush' in report operations or report orders complete. When the quantity is backflushed....

Increase Production by 10-20% - It's Simple!

Developed for Infor LX, BPCS, Infor LN, Baan & Infor M3

Crossroads RMC 0 27569 Article rating: 5.0

Studies show that merely displaying current production data to your workers via a dashboard increases production.

Improve the performance of your shop floor with Analytics Dashboard for Infor LX, BPCS, Infor LN, Baan, and Infor M3. It's simple to use and configure without programming knowledge. Display performance metrics in a grid, graph, chart, or any way that makes sense. learn more>

Infor LX & BPCS Manufacturing Tip: Production Register Listing

George Moroses 0 25888 Article rating: 5.0

Use the Production Register Listing screen, JIT610D1-01, to print an edit list of the labor tickets that you added or updated. Use this report to see the data to post before you actually perform the update. After you print the edit list, you can go back to Production Reporting (JIT600) and change the data before you post the batch. The program assigns a number to each production report that you posted in JIT600. You can use JIT600 to reference the production report that you want to update. Access: Specify Post on Production Reporting, JIT600D1-01.

RSS
First5960616264666768Last